OPERATION: Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, flows to the water
reservoir which it enters through the float valve.
The water then goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain. Water cooled models have a
separate water circuit for the cooling water: it
enters the fitting at the rear, goes to the water
regulating valve, then to the water cooled
condenser and down the drain.
The storage bin has a separate drain tube and
drain fitting.
NSE654
January 2000
Page 12
EVAPORATOR
DRAIN
WATER LEVEL
ICE
CHUTE
DRAIN
WATER SCHEMATIC
RESERVOIR
Water Level: The correct water level should be
checked when the machine is making ice. Check the
water level in the reservoir and compare it to the
horizontal line molded into the side of the reservoir.
The correct water level is between
1
8
" above and
1
4
"
below the line. If needed, bend the float arm up or
down to adjust the water level.