TRANSDUCER
LOCATION
TRANSDUCER
REMOVAL OF TRANSDUCER
PLUG
CONNECTION
TRANSDUCER
SOCKET
REMOVAL AND REPLACEMENT
TRANSDUCER
1. Disconnect electrical power BEFORE removing
transducer.
2. Open bin door and locate the transducer socket.
3. Twist inner portion of transducer counter-
clockwise and push up gently.
4. Pull transponder down until plug connection is
accessible.
5. Unplug transducer and remove from the
machine.
6. Reverse steps 1-5 to reassemble.